8912 Westglen Dr
Dallas, TX 75228
70 feet of cast-iron pipe to be replaced at Dallas home
A residential plumbing permit indicates that 70 feet of cast-iron pipe beneath a pier-and-beam home at 8912 Westglen Dr will be replaced with PVC. The City of Dallas permit was filed July 14, 2026.
Summarized from City of Dallas records · updated Jul 14, 2026
- Projects
- 1
- 1 filings
- Latest filing
- Jul 14, 2026
- since Jul 14, 2026
- Largest scope
- —
- Listed value
- —
Permit & project history
1 projectSources: City of Dallas
Questions about 8912 Westglen Dr
What work is permitted at 8912 Westglen Dr in Dallas?
The permit describes replacing 70 feet of cast-iron pipe with PVC beneath a pier-and-beam home. It was filed with the City of Dallas on July 14, 2026.
Is a new home being built at 8912 Westglen Dr?
The record is for a residential plumbing permit, not a new-home construction permit. It covers replacing pipe beneath an existing pier-and-beam home.
What kind of plumbing work is planned at 8912 Westglen Dr?
The work description says 70 feet of cast-iron pipe beneath the home will be replaced with PVC.
When was the plumbing permit filed for 8912 Westglen Dr?
The City of Dallas permit was filed July 14, 2026. Its permit number is RES-PLM-26-007271.
What is the permit number for work at 8912 Westglen Dr?
The permit number is RES-PLM-26-007271. The City of Dallas record describes a replacement of 70 feet of cast-iron pipe with PVC beneath a pier-and-beam home.
Also being built nearby
All of 75228- 8821 Westglen DrApr 16, 2026Upgrade the panel to 200amps, overhead service · 81 m away
- 9015 Westglen DrApr 28, 2026Water heater replacement · 109 m away
- 8903 Vinewood DrJul 23, 2026Electrical repairs · 109 m away
- 8915 Stanwood DrJul 21, 2026Nsfaa the balcony is an elevated, wood-framed structure. its outboard edge is carried by a built-up girder composed of threeplies of 1-3/4 inch by 18 inch laminated veneer lumber (lvl), which bears on existing steel columns. the balcony floorjoists frame into this girder and are attached with metal joist hangers. a stone deck finish over a self-adheredwaterproofing membrane was installed above the framing at the top of the girder.ces observed advanced, moisture-driven decay of the lvl girder. the individual plies have delaminated and separated,and over substantial portions of the member the wood has deteriorated to a soft, fibrous condition, with areas reduced toloose and friable debris. this deterioration is consistent with prolonged entrapment of water within the girder beneath thedeck finish and membrane. laminated veneer lumber is an interior product and is not manufactured for sustained exposureto moisture.based on these observations, it is ces’s professional opinion that the girder has sustained a significant loss of cross-section and can no longer be relied upon to safely support the balcony. given the extent and distribution of the decay, alocalized or partial repair is not appropriate, and the girder must be removed and replaced in its entirety. until the memberis shored, the balcony should be treated as structurally compromised, and foot traffic and imposed loads should be keptoff of it.before the girder is removed, the balcony floor joists must be temporarily shored to relieve the existing girder of all load.ces recommends wood shoring consisting of 4x6 posts spaced at 24 inches on center, set on a continuous 2x6 bottom(sill) plate and supporting a continuous double 2x6 top plate positioned against the underside of the joists just inboard ofthe girder. the shoring shall bear on a firm, level surface capable of supporting the imposed loads, and it shall be plumbedand secured against displacement. the existing steel columns are to remain; they shall be independently braced to holdthem in position and to protect them from displacement or damage during removal of the girder and until the replacementgirder is fully installed.once the shoring and column bracing are in place and confirmed to be carrying the balcony load, the joist hangers andthe deteriorated three-ply lvl girder may be removed. a new girder consisting of three plies of 1-3/4 inch by 18 inchlvl, matching the existing member, shall be installed on the existing columns using connections equivalent to or betterthan the original. each floor joist shall then be reconnected to the new girder with new galvanized joist hangers of theappropriate size. the temporary shoring and column bracing shall remain in place until the new girder and all joistconnections are complete.because the original failure resulted from moisture reaching and remaining in contact with the lvl, the replacementgirder must be protected against a recurrence. the new girder and the adjacent framing shall be fully flashed and integratedwith a continuous, properly lapped waterproofing membrane, and the deck assembly shall be detailed to drain waterpositively away from the framing. any concealed source of water that contributed to the original deterioration should beidentified and corrected as part of this work.these recommendations are based on visual observation of the accessible conditions and on the photographs provided;ces has not performed an analysis of the remaining capacity of the existing framing or an evaluation of concealedconditions beyond those exposed. the contractor is responsible for the means, methods, sequencing, and safety of theshoring and demolition operations, including compliance with applicable osha requirements · 110 m away
- 8915 Vinewood DrNov 3, 2025Replacing furnace, evap coil and condenser. adding return air duct · 110 m away
- 8906 Stanwood DrJun 11, 2025Electrical service repair due to storm damages · 112 m away
- 9026 Westglen DrNov 26, 2025Tunnel up to 10 feet under structure and repair one hot side water leak · 122 m away
- 9025 Westglen DrJun 26, 2026Drain leak spot repair · 123 m away
- 9029 Westglen DrOct 26, 2026Reroute the kitchen and laundry, tunneling to repipe the 2 bathrooms, replacing the entire yard service line · 128 m away
- 8811 Vinewood DrJun 25, 2026One 40 gallon gas water heater in hallway closet · 130 m away
- 9032 Westglen DrJun 4, 2026Wire swimming pool · 131 m away
- 8823 Stanwood DrOct 21, 2026Install inground awimming pool and spa · 132 m away