6508 Skillman St
Dallas, TX 75231
Electrical disconnect repair permitted at 6508 Skillman St
A City of Dallas permit indicates repair work on the existing electrical disconnect at 6508 Skillman St. The commercial electrical permit was filed June 27, 2025; the record does not describe a new building or provide a project cost.
Summarized from City of Dallas records · updated Jun 27, 2025
- Projects
- 1
- 1 filings
- Latest filing
- Jun 27, 2025
- since Jun 27, 2025
- Largest scope
- —
- Listed value
- —
Permit & project history
1 projectSources: City of Dallas
Questions about 6508 Skillman St
What is being built at 6508 Skillman St in Dallas?
The permit record describes repair of the existing electrical disconnect, not construction of a new building. The permit was filed June 27, 2025.
What work was permitted at 6508 Skillman St?
A City of Dallas commercial electrical permit covers repair of the existing electrical disconnect. Its permit number is COM-ELC-25-000597.
When was the 6508 Skillman St permit filed?
The permit was filed on June 27, 2025.
Is a new building going up at 6508 Skillman St?
The available permit describes repair of an existing electrical disconnect. It does not indicate construction of a new building.
How much will the work at 6508 Skillman St cost?
The permit record does not list a project valuation or estimated cost.
Also being built nearby
All of 75231- 6500 Skillman StAug 18, 2026Bathroom addition to existing plumbing toilet, floor drain, and lavatory. pull existing fixtures in place and install new in same locations. four toilets, three lavatories · 32 m away
- 6506 Skillman StSep 23, 2026Interior renovation for restaraunt includes kitchen & restrooms · 75 m away
- 6928 Walling LnDec 15, 2025Replacing one 50 gal water heater in garage · 192 m away
- 6750 Abrams RdOct 16, 2020Erect attached sign · 214 m away
- 7041 Kingsbury DrJun 2, 202614.3 seer upflow 2 ton gas system · 217 m away
- 6940 Walling LnJul 1, 2025Foundation repair installing 14 piers · 241 m away
- 6760 Abrams RdMar 26, 2026Commercial plumbing permit · 242 m away
- 6510 Abrams RdAug 24, 2026Make safe from demolition, tie in existing lights. new outlet in new office · 247 m away
- 7023 Kingsbury DrAug 31, 2026Complete electrical service change for both dwelling units of a two-family duplex at 7021 and 7023 kingsbury dr. each unit is currently served by a 150 amp fused service with a federal pacific stab-lok load center located in a clothes closet. the scope below is performed twice, once per dwelling unit.service, 2 required: remove the existing fused service disconnect and obsolete meter socket at each unit. install two new service masts of 2 inch rigid metal conduit with weatherhead, point of attachment hardware, and roof flashing, connected to the existing overhead service drop. install new 2/0 copper service entrance conductors, three conductors per unit. install two new 200 amp ringless meter-main combinations (square d rc200s with 200 amp main breaker), one per unit, on the exterior rear wall, each set within the utility required meter height and each serving as the service disconnecting means for its own unit. each marked per nec 230.85. each meter socket permanently identified with its unit address per utility requirements for multi-metered locations.load centers, 2 required: remove both existing federal pacific stab-lok load centers from clothes closets. install two new 42 space main lug load centers, 225 amp bus, one per unit, at code compliant locations. each supplied by a 200 amp feeder of 4/0 aluminum ser, approximately 60 feet per unit, from that unit's service disconnect. each existing panel enclosure to be retained as an accessible junction box with blank cover. existing branch circuits to be spliced and extended to the new load center, then identified and labeled with a circuit directory per nec 408.4(a). approximately 18 branch circuits per unit.grounding and bonding, 2 required: new grounding electrode system at each unit consisting of two 8 foot driven ground rods, #4 bare copper grounding electrode conductor sized per nec 250.66, water pipe bond, and intersystem bonding termination. each load center neutral isolated from equipment ground per nec 250.24 and 250.142.other: install a whole panel surge protective device at each load center per nec 230.67. install branch circuit overcurrent devices. coordinate meter removal and reset with oncor for both meters.existing branch circuit conductors remain in place. no branch circuit rewiring is included in this scope · 247 m away
- 6523 Abrams RdNov 20, 2025Requesting power release for existing commercial space. no electrical work performed. clean & show (as-is) · 259 m away
- 6946 Walling LnNov 4, 2025Replace 200a oh meter, add 225a exterior disconnect, 100ft ug to new 125a sub panel, 2 ground rods, cold water bond, intersystem, surge · 259 m away
- 6666 Skillman StJan 28, 2021Gas relay or repair with test · 266 m away