Permit filed for a 2-ton gas HVAC system
A residential mechanical permit records a 14.3 SEER upflow 2-ton gas system at 7041 Kingsbury Dr. The City of Dallas permit was filed June 2, 2026, under permit RES-MEC-26-002685.
Summarized from City of Dallas records · updated Jun 2, 2026
- Projects
- 1
- 1 filings
- Latest filing
- Jun 2, 2026
- since Jun 2, 2026
- Largest scope
- —
- Listed value
- —
Permit & project history
1 projectSources: City of Dallas
Questions about 7041 Kingsbury Dr
What is being built at 7041 Kingsbury Dr?
A City of Dallas residential mechanical permit records a 14.3 SEER upflow 2-ton gas system. It does not describe a new building.
What kind of HVAC system is listed for 7041 Kingsbury Dr?
The permit description lists a 14.3 SEER upflow 2-ton gas system.
When was the permit filed for 7041 Kingsbury Dr?
The City of Dallas permit was filed June 2, 2026.
What is the permit number for 7041 Kingsbury Dr?
The permit number is RES-MEC-26-002685. It is classified as a residential mechanical permit.
Is a new home being built at 7041 Kingsbury Dr?
The available record is for a residential mechanical system, not a new home construction permit.
Is this a commercial project at 7041 Kingsbury Dr?
The record classifies the work as residential and lists a 2-ton gas system.
Also being built nearby
All of 75231- 7023 Kingsbury DrAug 31, 2026Complete electrical service change for both dwelling units of a two-family duplex at 7021 and 7023 kingsbury dr. each unit is currently served by a 150 amp fused service with a federal pacific stab-lok load center located in a clothes closet. the scope below is performed twice, once per dwelling unit.service, 2 required: remove the existing fused service disconnect and obsolete meter socket at each unit. install two new service masts of 2 inch rigid metal conduit with weatherhead, point of attachment hardware, and roof flashing, connected to the existing overhead service drop. install new 2/0 copper service entrance conductors, three conductors per unit. install two new 200 amp ringless meter-main combinations (square d rc200s with 200 amp main breaker), one per unit, on the exterior rear wall, each set within the utility required meter height and each serving as the service disconnecting means for its own unit. each marked per nec 230.85. each meter socket permanently identified with its unit address per utility requirements for multi-metered locations.load centers, 2 required: remove both existing federal pacific stab-lok load centers from clothes closets. install two new 42 space main lug load centers, 225 amp bus, one per unit, at code compliant locations. each supplied by a 200 amp feeder of 4/0 aluminum ser, approximately 60 feet per unit, from that unit's service disconnect. each existing panel enclosure to be retained as an accessible junction box with blank cover. existing branch circuits to be spliced and extended to the new load center, then identified and labeled with a circuit directory per nec 408.4(a). approximately 18 branch circuits per unit.grounding and bonding, 2 required: new grounding electrode system at each unit consisting of two 8 foot driven ground rods, #4 bare copper grounding electrode conductor sized per nec 250.66, water pipe bond, and intersystem bonding termination. each load center neutral isolated from equipment ground per nec 250.24 and 250.142.other: install a whole panel surge protective device at each load center per nec 230.67. install branch circuit overcurrent devices. coordinate meter removal and reset with oncor for both meters.existing branch circuit conductors remain in place. no branch circuit rewiring is included in this scope · 36 m away
- 7009 Kingsbury DrAug 5, 2025Replaced federal pacific panel & disconnect with up to code electrical panel · 63 m away
- 6409 Larmanda StAug 3, 2026Tear out only marked in yellow install new 8' tall cedar board on board marked in red along side and back of property post set 24" deep in concrete and at 6' centers no gates · 95 m away
- 7055 Winchester StMay 22, 2025Install 4 total pilingsfoundation repair only, no layout changes allowed.all work subject to field inspector approval. foundation repair only, no layout changes allowed · 103 m away
- 7043 Winchester StJan 26, 2021Remove existing roof and install new roof · 107 m away
- 7036 Winchester StNov 24, 2025Gas test · 122 m away
- 6928 Walling LnDec 15, 2025Replacing one 50 gal water heater in garage · 122 m away
- 7030 Winchester StJul 22, 2025Replace 2 ton complete · 125 m away
- 6953 Kingsbury DrDec 1, 2020Replace or modify existing hvac · 156 m away
- 6940 Walling LnJul 1, 2025Foundation repair installing 14 piers · 156 m away
- 6941 Kingsbury DrApr 9, 2026Replacing cast iron under the home · 172 m away
- 6946 Walling LnNov 4, 2025Replace 200a oh meter, add 225a exterior disconnect, 100ft ug to new 125a sub panel, 2 ground rods, cold water bond, intersystem, surge · 172 m away