6500 Skillman St
Dallas, TX 75231
6500 Skillman St remodel expands into adjacent 3,488-sq-ft space
A commercial remodel at 6500 Skillman St will expand into an adjacent 3,488-square-foot space, according to a permit filed July 6, 2026. The permit describes a total 28,892-square-foot space and a sliding door system at the west-side donation drop-off. Later permits filed in July and August cover lighting, HVAC, and plumbing work.
Summarized from City of Dallas records · updated Aug 18, 2026
- Projects
- 4
- 4 filings
- Latest filing
- Aug 18, 2026
- since Jul 6, 2026
- Largest scope
- —
- Listed value
- —
Permit & project history
4 projectsBathroom addition to existing plumbing toilet, floor drain, and lavatory. pull existing fixtures in place and install new in same locations. four toilets, three lavatories
Bathroom addition to existing plumbing toilet, floor drain, and lavatory. pull existing fixtures in place and install new in same locations. four toilets, three lavatories
City of Dallas permitCommercial Plumbing PermitZo bc a 25,404-sq ft remodel expanding into the adjacent 3,488-sq ft space for a total of28,892-sq ft a sliding door system will be added on the west side at donationdrop-off. project will include minimal exterior concrete work to allow forrolling carts in and out of the building/drive-through area
Zo bc a 25,404-sq ft remodel expanding into the adjacent 3,488-sq ft space for a total of28,892-sq ft a sliding door system will be added on the west side at donationdrop-off. project will include minimal exterior concrete work to allow forrolling carts in and out of the building/drive-through area
City of Dallas permitCommercial Alteration Addition Permit
Sources: City of Dallas
Questions about 6500 Skillman St
What is being built at 6500 Skillman St?
A commercial alteration permit describes a remodel expanding into an adjacent 3,488-square-foot space, for a total of 28,892 square feet. It also describes a sliding door system at the west-side donation drop-off.
When was the remodel at 6500 Skillman St permitted?
The commercial alteration permit, COM-ALT-ADD-26-001397, was filed July 6, 2026.
How large is the project at 6500 Skillman St?
The alteration permit describes a 25,404-square-foot remodel expanding into a 3,488-square-foot adjacent space, for a total of 28,892 square feet.
What other work is permitted at 6500 Skillman St?
Permits filed July 7 and July 14, 2026, cover replacement light fixtures and existing HVAC units and ductwork. An August 18 plumbing permit describes bathroom fixture work.
What plumbing work is planned at 6500 Skillman St?
Permit COM-PLM-26-003195, filed August 18, 2026, describes work on four toilets and three lavatories, along with a floor drain. Existing fixtures are to be replaced in the same locations.
Also being built nearby
All of 75231- 6508 Skillman StJun 27, 2025Repairing of the existing electrical disconnect · 32 m away
- 6506 Skillman StSep 23, 2026Interior renovation for restaraunt includes kitchen & restrooms · 67 m away
- 6928 Walling LnDec 15, 2025Replacing one 50 gal water heater in garage · 205 m away
- 7041 Kingsbury DrJun 2, 202614.3 seer upflow 2 ton gas system · 211 m away
- 6510 Abrams RdAug 24, 2026Make safe from demolition, tie in existing lights. new outlet in new office · 219 m away
- 6750 Abrams RdOct 16, 2020Erect attached sign · 226 m away
- 6523 Abrams RdNov 20, 2025Requesting power release for existing commercial space. no electrical work performed. clean & show (as-is) · 229 m away
- 6515 Abrams RdJun 30, 2025Tap into lighting circuit to power an ex fan. label panel · 238 m away
- 7023 Kingsbury DrAug 31, 2026Complete electrical service change for both dwelling units of a two-family duplex at 7021 and 7023 kingsbury dr. each unit is currently served by a 150 amp fused service with a federal pacific stab-lok load center located in a clothes closet. the scope below is performed twice, once per dwelling unit.service, 2 required: remove the existing fused service disconnect and obsolete meter socket at each unit. install two new service masts of 2 inch rigid metal conduit with weatherhead, point of attachment hardware, and roof flashing, connected to the existing overhead service drop. install new 2/0 copper service entrance conductors, three conductors per unit. install two new 200 amp ringless meter-main combinations (square d rc200s with 200 amp main breaker), one per unit, on the exterior rear wall, each set within the utility required meter height and each serving as the service disconnecting means for its own unit. each marked per nec 230.85. each meter socket permanently identified with its unit address per utility requirements for multi-metered locations.load centers, 2 required: remove both existing federal pacific stab-lok load centers from clothes closets. install two new 42 space main lug load centers, 225 amp bus, one per unit, at code compliant locations. each supplied by a 200 amp feeder of 4/0 aluminum ser, approximately 60 feet per unit, from that unit's service disconnect. each existing panel enclosure to be retained as an accessible junction box with blank cover. existing branch circuits to be spliced and extended to the new load center, then identified and labeled with a circuit directory per nec 408.4(a). approximately 18 branch circuits per unit.grounding and bonding, 2 required: new grounding electrode system at each unit consisting of two 8 foot driven ground rods, #4 bare copper grounding electrode conductor sized per nec 250.66, water pipe bond, and intersystem bonding termination. each load center neutral isolated from equipment ground per nec 250.24 and 250.142.other: install a whole panel surge protective device at each load center per nec 230.67. install branch circuit overcurrent devices. coordinate meter removal and reset with oncor for both meters.existing branch circuit conductors remain in place. no branch circuit rewiring is included in this scope · 238 m away
- 6419 Skillman SreetJun 20, 2025Tesla - dallas, tx - skillman — new construction — electrical infrastructure · 245 m away
- 6419 Skillman StSep 21, 2026Drive approach replacement · 245 m away
- 7009 Kingsbury DrAug 5, 2025Replaced federal pacific panel & disconnect with up to code electrical panel · 254 m away