9609 Walnut St
Dallas, TX 75243
Backflow device replaced at Building 10 on Walnut Street
A commercial plumbing permit covers replacement of an in-ground double-check backflow device at the end of Building 10 at 9609 Walnut St. The City of Dallas permit was filed July 7, 2025, under permit number COM-PLM-25-000661.
Summarized from City of Dallas records · updated Jul 7, 2025
- Projects
- 1
- 1 filings
- Latest filing
- Jul 7, 2025
- since Jul 7, 2025
- Largest scope
- —
- Listed value
- —
Permit & project history
1 projectSources: City of Dallas
Questions about 9609 Walnut St
What work was permitted at 9609 Walnut St in Dallas?
The permit covers replacing an in-ground double-check backflow device at the end of Building 10. It was filed July 7, 2025.
Is a new building being built at 9609 Walnut St?
The record describes plumbing work at Building 10: replacement of a double-check backflow device. It does not describe construction of a new building.
When was the plumbing permit filed for 9609 Walnut St?
The City of Dallas filed the commercial plumbing permit on July 7, 2025.
What is the permit number for work at 9609 Walnut St?
The permit number is COM-PLM-25-000661. It covers replacement of a double-check backflow device at Building 10.
Where at 9609 Walnut St is the backflow device being replaced?
The permit description places the in-ground device at the end of Building 10.
Also being built nearby
All of 75243- 9603 Walnut StNov 14, 2025Near building 9603: double check installation near building. area is dug up, valve and box in place and covered · 32 m away
- 9601 Walnut StNov 13, 2026Mcr the community consists of 12 buildings. 5 of the buildings are 3 story. these buildings are #1, #5, #10. #11, and #12. each building has 3 exterior front side stairwells. the foundations under the stairs are failing. this is causing the stairs to sink, and pull away from the buildings. this situation has caused water to leak between the stair landings and the entry landings. the connection to the building is in part the cause of the leaks as well. consequently there are varied degrees of water damage to the entry landings, and to related structures in immediate vicinity of landings. we intend to demolition all stucco from the stairwells. lift, and support the stairwells while the existing foundation is removed, and new foundation is installed. repair or replace damage steel supports as needed. make repairs to existing building as needed. install new hand railings to code, and paint.due to financial restrictions the hoa wants to do 1 building at a time, (3 stairwells). this is the reason for the phased project · 43 m away
- 9696 Walnut StOct 31, 2025Replace 2 ton heat pump wall mount system · 218 m away
- 9751 Walnut StFeb 9, 2026Came out today because eden is trying to get power turned on to her business suit that she recently acquired. oncor is requiring a city inspection before they will turn on power. i advised eden that we could pull the permit but would need to inspect the building for any potential violations that would cause the city inspection to fail. built estimate and looked over everything, found (2) open splices above the drop tile ceiling and a few other items. repaired those items and closed everything back up. we are now ready for the inspection. if the city requires additional work to be done, we will build additional estimates. no issues at close · 360 m away
- 13015 Audelia RdSep 20, 2026Replace double check valve outside of building 6 · 412 m away
- 12995 Audelia RdSep 8, 2026Install electrical service for a charter power supply cabinet per oncor · 415 m away
- 9780 Walnut StSep 4, 2026Repaired gas valve leak for furnace on the roof · 434 m away
- 12920 Audelia RdFeb 13, 2026Install 4 total pilings · 442 m away
- 9788 Walnut St · Lee And Walnut Assoc LtdSep 16, 2026Clean/show · 454 m away
- 13015 Halwin CirJul 6, 2026Drain sewer repipe · 488 m away
- 12516 Audelia RdNov 2, 2026Mcr fire damage repair at huntington brook apartments, building 10 (r-2, type va, ). unit 1012 (fire origin, 2nd floor): replace fire-damaged roof trusses (engineered by truss manufacturer), roof decking, underlayment and asphalt shingles; new drywall throughout walls and ceilings; new interior doors and flooring; new electrical wiring, receptacles, switches, light fixtures, smoke detectors and 125a panel; new hvac condenser, air handler and ductwork; replace plumbing fixtures like-for-like; repair exterior fiber cement siding, soffit, fascia and gutters. unit 1011 (water/smoke damage): new drywall throughout, paint, new interior doors and flooring; replace outlets, switches and plumbing fixtures as needed; existing hvac and plumbing lines to remain. unit 1010 (smoke damage): attic insulation, drywall texture, flooring and paint repairs. attic: clean, seal and deodorize trusses; replace blown-in insulation. no change of use, no added floor area or dwelling units · 493 m away
- 13002 Halwin CirJul 8, 2025Gas test · 499 m away