17523 Oak Mount Pl
Dallas, TX 75287
Roof replacement permitted at 17523 Oak Mount Pl
A residential roofing permit was filed for work at 17523 Oak Mount Pl on November 7, 2025. The permit describes removing the existing composition roofing and installing 30-pound felt and granite-gray Decra Shake roofing, listed as 50-year.
Summarized from City of Dallas records · updated Nov 7, 2025
- Projects
- 1
- 1 filings
- Latest filing
- Nov 7, 2025
- since Nov 7, 2025
- Largest scope
- —
- Listed value
- —
Permit & project history
1 projectSources: City of Dallas
Questions about 17523 Oak Mount Pl
What is being built at 17523 Oak Mount Pl?
A City of Dallas residential roofing permit describes a roof replacement at the address, not a new building.
When was the roof permit filed for 17523 Oak Mount Pl?
The permit was filed on November 7, 2025.
What roofing material is planned at 17523 Oak Mount Pl?
The permit describes 30-pound felt and granite-gray Decra Shake roofing, listed as 50-year.
What is the permit number for the roofing work?
The City of Dallas permit number is RES-ROOF-25-001144, filed November 7, 2025.
Is a new home being built at 17523 Oak Mount Pl, Dallas, TX 75287?
The available record is a residential roofing permit for the existing address; it does not describe construction of a new home.
Also being built nearby
All of 75287- 17515 Oak Mount PlDec 2, 2025Install 3 50-gal gas water heater 2 upstair middle closet and left closet 1 downstairs closet · 19 m away
- 17531 Oak Mount PlJun 8, 2026Replacing 4 ton furnace only · 19 m away
- 17503 Woods Edge DrNov 13, 2026Gen gas line · 42 m away
- 17507 Oak Mount PlMar 4, 2026Replace water heater · 45 m away
- 17508 Oak Mount PlApr 20, 2026Reroof · 46 m away
- 17531 Woods Edge DrJul 16, 2025Installed 50 gallon gas water heater in garage closet · 47 m away
- 17532 Woods Edge DrSep 28, 2026Re-roof · 64 m away
- 17504 Ivy Hill DrOct 22, 2025Electrical permit required to close primary record res-solar-25-000307 for residential solar/pv.electrical scope of work has already been reviewed and approved as part of primary record. mcr with battery design and installation of a grid-tied residential solar photovoltaic (pv) system with battery energy storage at 17504 ivy hill drive, dallas, tx 75287. the proposed system consists of 21 meyer burger black 390 w monocrystalline pv modules mounted on the existing pitched asphalt shingle roof using the snapnrack topspeed original racking system. the modules will be installed in one contiguous array on the south-west facing 1st-story roof slope of the attached garage, at a tilt matching the roof pitch of 33°. the pv modules will be electrically connected in series to form strings that feed into an eg4 flexboss 21 hybrid inverter, which will be coupled to an eg4 gridboss microgrid interconnect device and an eg4 powerpro indoor wall-mounted lithium-ion battery for on-site energy storage and backup capability. the system will be interconnected to the utility grid in compliance with nec article 705 for grid-interactive systems, but will not allow excess generation to be exported to the grid. the total system capacity is 8.19 kw dc (390 w × 21 modules). the inverter’s ac output will be connected to the home’s existing electrical service panel via a dedicated solar breaker in accordance with nec 690.64(b) and 705.12(b). conductor sizes, overcurrent protection, and disconnects are selected to meet nec requirements for ampacity and safety. structural loading calculations, based on the 2021 international building code (), asce 7-16, and local amendments, confirm that the added distributed load of 2.41 psf from the pv system is well within allowable limits for the existing roof structure. the snapnrack topspeed racking system is designed and installed per the manufacturer’s installation manual and will provide wind uplift resistance for a basic design wind speed of 106 mph (exposure category b) and a ground snow load of 10 psf. all equipment used in this installation is ul-listed and compliant with the most recent nec, , and city of dallas building and electrical codes. the system will include nec-compliant labeling and placards for rapid shutdown, pv source circuits, ac disconnects, and battery storage. this project will provide the homeowner with renewable energy generation, reduced utility bills, and battery backup capability for resiliency during power outages, while meeting all safety, structural, and code requirements for rooftop solar installations in the city of dallas · 84 m away
- 17524 Ivy Hill DrNov 26, 2025Foundation repair-install 7 pilings · 112 m away
- 17427 Woods Edge DrFeb 12, 2026Gas test & repair · 115 m away
- 17532 Ivy Hill DrSep 16, 2026Hvac ac replacement · 118 m away
- 17423 Woods Edge DrMay 11, 2026Replace 3 50 gallon gas water heaters, 1 located on first floor in garage, 2 in attic above first floor · 119 m away