groundranger
Recent · latest filing Dec 2025Residential

5717 Louise Ln

Austin, TX 78757

Solar panels and home battery system permitted on Louise Lane

A new grid-interactive solar and energy-storage system was permitted at 5717 Louise Ln on December 15, 2025. The plans describe a 9.68 kW DC solar system, two batteries for whole-home backup, and an inverter; the existing solar system will remain in place.

Summarized from City of Austin records · updated Dec 15, 2025

Projects
1
1 filings
Latest filing
Dec 15, 2025
since Dec 15, 2025
Largest scope
—
Listed value
—

Where this project stands

Finaled

This project consists of installing a new grid-interactive photovoltaic and energy-storage system at 5717 louise ln austin tx in accordance with the attached planset and the. work includes electrical installation of a new 9.680 kw dc / 16.0 kw ac pv system consisting of (22) phono draco ps440m8gf-18/vnh modules each equipped with tigo ts4-a-o optimizers interconnected to a new eg4 flexboss 21 hybrid inverter. two eg4 14.3 kwh powerpro batteries and associated eg4 battery conduit boxes will be installed to provide whole-home backup via the eg4 gridboss gateway. all battery equipment is ul 9540 certified as shown in the planset. work includes routing new dc homeruns to a roof-mounted junction box installing an imo 4-pole dc disconnect installing ac conductors between the inverter gridboss and the existing 200a main service panel and landing the system on a dedicated backfeed breaker sized per inverter specifications. all grounding and bonding will follow nec 250 and 690 requirements. rapid shutdown functionality per nec 690.12 will be provided through module-level electronics. the existing pv systemcomprised of (30) canadian solar cs6k-280m modules with p300 optimizers a solaredge se7600 inverter pv meter and existing ac disconnectwill remain in place. no service upgrade main breaker derate structural modifications or roofing penetrations beyond those shown on the plans are included. all work will follow manufacturer installation requirements maintain nec-required clearances and be inspected prior to energization

  1. AppliedDec 8, 2025
  2. IssuedDec 15, 2025
  3. WorkDec '25 – Jun '26
  4. Final inspectionMar 6, 2026

Passed final inspection Mar 6, 2026.

1 contact on this project · 1 phone number

Permit & project history

1 project
  1. This project consists of installing a new grid-interactive photovoltaic and energy-storage system at 5717 louise ln austin tx in accordance with the attached planset and the. work includes electrical installation of a new 9.680 kw dc / 16.0 kw ac pv system consisting of (22) phono draco ps440m8gf-18/vnh modules each equipped with tigo ts4-a-o optimizers interconnected to a new eg4 flexboss 21 hybrid inverter. two eg4 14.3 kwh powerpro batteries and associated eg4 battery conduit boxes will be installed to provide whole-home backup via the eg4 gridboss gateway. all battery equipment is ul 9540 certified as shown in the planset. work includes routing new dc homeruns to a roof-mounted junction box installing an imo 4-pole dc disconnect installing ac conductors between the inverter gridboss and the existing 200a main service panel and landing the system on a dedicated backfeed breaker sized per inverter specifications. all grounding and bonding will follow nec 250 and 690 requirements. rapid shutdown functionality per nec 690.12 will be provided through module-level electronics. the existing pv systemcomprised of (30) canadian solar cs6k-280m modules with p300 optimizers a solaredge se7600 inverter pv meter and existing ac disconnectwill remain in place. no service upgrade main breaker derate structural modifications or roofing penetrations beyond those shown on the plans are included. all work will follow manufacturer installation requirements maintain nec-required clearances and be inspected prior to energization

    This project consists of installing a new grid-interactive photovoltaic and energy-storage system at 5717 louise ln austin tx in accordance with the attached planset and the. work includes electrical installation of a new 9.680 kw dc / 16.0 kw ac pv system consisting of (22) phono draco ps440m8gf-18/vnh modules each equipped with tigo ts4-a-o optimizers interconnected to a new eg4 flexboss 21 hybrid inverter. two eg4 14.3 kwh powerpro batteries and associated eg4 battery conduit boxes will be installed to provide whole-home backup via the eg4 gridboss gateway. all battery equipment is ul 9540 certified as shown in the planset. work includes routing new dc homeruns to a roof-mounted junction box installing an imo 4-pole dc disconnect installing ac conductors between the inverter gridboss and the existing 200a main service panel and landing the system on a dedicated backfeed breaker sized per inverter specifications. all grounding and bonding will follow nec 250 and 690 requirements. rapid shutdown functionality per nec 690.12 will be provided through module-level electronics. the existing pv systemcomprised of (30) canadian solar cs6k-280m modules with p300 optimizers a solaredge se7600 inverter pv meter and existing ac disconnectwill remain in place. no service upgrade main breaker derate structural modifications or roofing penetrations beyond those shown on the plans are included. all work will follow manufacturer installation requirements maintain nec-required clearances and be inspected prior to energization

    City of Austin permitElectrical PermitFinal
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro

Sources: City of Austin

Questions about 5717 Louise Ln

What is being installed at 5717 Louise Ln?

A City of Austin electrical permit describes a new grid-interactive solar and energy-storage system at the home. The plans include solar panels, an inverter, and two batteries for whole-home backup.

When was the solar system at 5717 Louise Ln permitted?

The City of Austin permit, 2025-155268 EP, was filed on December 15, 2025. Its status is listed as final.

How large is the new solar system at 5717 Louise Ln?

The permit describes a 9.68 kW DC, 16.0 kW AC photovoltaic system with 22 solar modules.

Will 5717 Louise Ln have a home battery?

Yes. The permit plans include two 14.3 kWh batteries and equipment for whole-home backup.

Will the existing solar panels at 5717 Louise Ln be removed?

No. The permit states that the existing photovoltaic system will remain in place while the new system is installed.