5718 Louise Ln
Austin, TX 78757
Electrical panel changeout at 5718 Louise Ln
A main electrical panel changeout was permitted at this Austin residence on September 28, 2026. The active City of Austin electrical permit is 2026-125426 EP; an earlier permit covered replacement of the central heating and air system and was finalized December 9, 2024.
Summarized from City of Austin records · updated Sep 28, 2026
- Projects
- 2
- 2 filings
- Latest filing
- Sep 28, 2026
- since Dec 9, 2024
- Largest scope
- —
- Listed value
- —
Where this project stands
Permit active · work underwayMain panel changeout
- AppliedSep 23, 2026
- IssuedSep 28, 2026
- WorkSep '26 – Mar '27
- Final inspection
1 contact on this project · 1 phone number
Permit & project history
2 projectsMain panel changeout
Main panel changeout
City of Austin permitElectrical PermitActive- Record
- 2026-125426 EP
- Owner
- Pro
- Contractor
- Pro
- Contact
- Pro
Replacement of complete existing central heat and air system with or without duct work
Replacement of complete existing central heat and air system with or without duct work
City of Austin permitMechanical PermitFinal- Record
- 2024-154041 MP
- Owner
- Pro
- Contractor
- Pro
- Contact
- Pro
Sources: City of Austin
Questions about 5718 Louise Ln
What work is permitted at 5718 Louise Ln?
A City of Austin permit indicates a main electrical panel changeout. Permit 2026-125426 EP was filed September 28, 2026, and is listed as active.
Is a new home being built at 5718 Louise Ln?
The records provided show an electrical panel changeout, not a new-home construction permit.
When was the electrical panel permit filed for 5718 Louise Ln?
The City of Austin filed permit 2026-125426 EP on September 28, 2026.
What is the status of permit 2026-125426 EP?
The City of Austin lists the electrical permit for the main panel changeout as active.
Was HVAC work also permitted at 5718 Louise Ln?
Yes. Permit 2024-154041 MP covered replacement of the existing central heat and air system, with or without duct work. It was filed December 9, 2024, and is listed as final.
Also being built nearby
All of 78757- 5720 Louise LnDec 14, 2023Replace water line from the meter to the house · 24 m away
- 5704 Susie CtAug 6, 2025New inground swimming pool with reqd enclosure device · 37 m away
- 5702 Susie CtDec 4, 2024Install a new exhaust vent · 46 m away
- 5717 Louise LnDec 15, 2025This project consists of installing a new grid-interactive photovoltaic and energy-storage system at 5717 louise ln austin tx in accordance with the attached planset and the. work includes electrical installation of a new 9.680 kw dc / 16.0 kw ac pv system consisting of (22) phono draco ps440m8gf-18/vnh modules each equipped with tigo ts4-a-o optimizers interconnected to a new eg4 flexboss 21 hybrid inverter. two eg4 14.3 kwh powerpro batteries and associated eg4 battery conduit boxes will be installed to provide whole-home backup via the eg4 gridboss gateway. all battery equipment is ul 9540 certified as shown in the planset. work includes routing new dc homeruns to a roof-mounted junction box installing an imo 4-pole dc disconnect installing ac conductors between the inverter gridboss and the existing 200a main service panel and landing the system on a dedicated backfeed breaker sized per inverter specifications. all grounding and bonding will follow nec 250 and 690 requirements. rapid shutdown functionality per nec 690.12 will be provided through module-level electronics. the existing pv systemcomprised of (30) canadian solar cs6k-280m modules with p300 optimizers a solaredge se7600 inverter pv meter and existing ac disconnectwill remain in place. no service upgrade main breaker derate structural modifications or roofing penetrations beyond those shown on the plans are included. all work will follow manufacturer installation requirements maintain nec-required clearances and be inspected prior to energization · 55 m away
- 5721 Louise LnMar 3, 2025Excavate 40 tunnel and repair all the cast iron that left in this house. its about 30 ft and then we will have to jet the kitchen line all the way to the clean out and from the clean out to the city · 56 m away
- 5715 Louise LnFeb 19, 2025Dig with excavator and hands cut a concrete portion garage sidewalk and replace 45 ft of 4 cast iron pipe with pvc 1. 45 ft long 2. 4 cast iron pipe 3. big roots in middle way 4. 811 marks will be needed 5. permits and testing will be required 6. cover everything after finish · 67 m away
- 5803 Fairlane DrMay 31, 202660 amp circuit for tesla ev charger located in the garage. main panel is located on backside of home. conduit will be routed through the attic space from main electrical panel to ev charger location in garage · 86 m away
- 5711 Fairlane DrAug 28, 2026Base: installing a backup battery system and additional meter socket · 94 m away
- 5707 Fairlane DrNov 4, 2026New construction of 1 story accessory structure · 98 m away
- 5703 Fairlane DrMay 1, 2024Replacement of complete existing central heat and air system with or without duct work · 102 m away
- 5710 Fairlane DrFeb 25, 2026Gas line for standby generator installation · 103 m away
- 5802 Marilyn DrApr 29, 2024Tunnel front to back both sides approximately 117 feet for repair job · 104 m away