3118 Jerome St
Dallas, TX 75223
Demolition and new-house permits at 3118 Jerome St
Dallas permits indicate residential demolition and new-house construction at 3118 Jerome St. A demolition permit was filed June 18, 2026, followed by a new-construction permit on November 10, 2026 (RES-NEW-26-002014).
Summarized from City of Dallas records · updated Nov 10, 2026
- Projects
- 6
- 6 filings
- Latest filing
- Nov 10, 2026
- since Jun 12, 2025
- Largest scope
- —
- Listed value
- —
Permit & project history
6 projectsSources: City of Dallas
Questions about 3118 Jerome St
What is being built at 3118 Jerome St in Dallas?
City of Dallas records include residential new-construction permits with descriptions indicating a new house. The latest was filed November 10, 2026, under permit RES-NEW-26-002014.
Was a house demolished at 3118 Jerome St?
The city record includes residential demolition permits filed June 18 and September 1, 2026, as well as an earlier demolition permit filed June 12, 2025.
When was the new house at 3118 Jerome St permitted?
New-construction permits were filed June 11 and November 10, 2026. The latest permit is RES-NEW-26-002014.
What permits have been filed for 3118 Jerome St?
The records include residential demolition, residential new-construction, and electrical permits. The electrical permit, RES-ELC-25-003179, was filed September 18, 2025, for rewiring the structure.
Is construction underway at 3118 Jerome St?
The records show a new-house permit filed November 10, 2026, but do not establish whether construction is underway.
Also being built nearby
All of 75223- 3111 Jerome StApr 10, 2026Nsfaa permitting for built addition from the past to comply with city of dallas rules and guidelines · 15 m away
- 3107 Jerome StFeb 27, 2026Electrical for addition · 18 m away
- 3111 Reynolds AveAug 12, 2025Perform gas test, for gas release · 91 m away
- 3027 Jerome StMar 10, 2026Electrical work for addition · 100 m away
- 3110 Kinmore StOct 31, 202540 gallon gas water heater · 112 m away
- 3011 Jerome StSep 25, 2025Gas test need atmos release · 117 m away
- 3203 Reynolds AveNov 10, 2026Nsfaa-bathroom addition · 134 m away
- 3014 Reynolds AveAug 28, 2025Scope of work by construction phase:1. pre-construction planning & permitting• perform manual j load calculation for heating/cooling loads.• prepare manual d duct design for air distribution.• select hvac equipment per manual s sizing standards.• submit equipment specifications, cut sheets, and duct layout with permit package to city of dallas.• coordinate with builder/general contractor for mechanical chase, soffit, and utility penetration planning.2. rough-in stage (prior to insulation & drywall)• install all supply and return ductwork (r-8 insulated flexible duct for unconditioned spaces, per dallas/).• install sheet metal trunk lines, plenums, and boots per manual d layout.• install refrigerant line sets between indoor air handler/coil and outdoor condensing unit.• run condensate drain lines to approved termination points (with primary & secondary drains per imc §307).• install bathroom exhaust fans, kitchen vent ductwork, and dryer vent duct with exterior termination.• frame and set hvac platform (attic or mechanical closet as per plans).• install combustion air ducts (if gas furnace is used).• install venting for furnaces and water heaters (category iv pvc or b-vent, as applicable).• install gas piping to furnace (if applicable) with sediment traps, shutoff valve, and pressure test per ifgc.• provide fresh air intake/mechanical ventilation system in compliance with dallas energy code.• seal all ductwork connections with mastic or ul-listed tape (per ).3. equipment installation• install air handler/furnace unit in attic or mechanical closet.• install outdoor condensing unit on approved pad or platform, meeting dallas setback and clearance requirements.• connect refrigerant lines, pressure test, and evacuate system prior to charging.• install line-set insulation with uv protection where exposed.• connect electrical whips, disconnects, breakers, and thermostat wiring per nec.• connect gas piping (if applicable), perform pressure test, and verify for leaks.• set and level drain pans with float switches and secondary drains.• install supply registers, return grilles, exhaust grilles in planned locations.________________________________________4. trim-out & final connections• install programmable thermostat(s) per requirements.• install final supply/return registers and grilles.• install bath exhaust fan trim kits and kitchen vent termination hood.• seal penetrations at ceiling/walls for air barrier integrity.• charge refrigerant system per manufacturer specs and dallas code requirements.• balance air distribution system to provide correct airflow to each room.• verify combustion air and venting operation (if gas furnace).• test condensate drains for proper slope and drainage.________________________________________5. testing, commissioning & final inspection• perform duct leakage testing per (? 4 cfm/100 sq ft at 25 pa).• perform airflow balancing for proper cfm per room.• test gas piping and connections for leaks.• verify thermostat and system operational controls.• provide manufacturer startup sheets, equipment model/serials, and balancing report to homeowner and inspector.• schedule city of dallas final inspection for mechanical systems.________________________________________owner-supplied vs. contractor-supplied• contractor will provide and install all hvac equipment, ductwork, registers, grills, refrigerant piping, gas piping, and associated materials unless otherwise noted.• builder/homeowner to coordinate mechanical chase framing and access to electrical service.exclusions• removal of asbestos or hazardous materials.• structural modifications not shown in hvac plans.• utility company fees for gas or electrical service upgrades · 153 m away
- 3014 Kinmore StDec 1, 2025Gas test for release · 156 m away
- 5219 St Charles AveNov 16, 2026Complete work from permit record 2306301067_181863593-003 · 157 m away
- 3218 Reynolds AveSep 12, 2025Remove all felt and replace with synthetic felt. remove all shingles and replace with iko architectural shingles. install new ice and water shield. install new drip edge. limited lifetime warranty · 164 m away
- 3007 Kinmore StFeb 25, 2026Gas test for service · 171 m away
More demolitions in 75223.