3122 Spurlock St
Dallas, TX 75223
HVAC component replacements permitted at 3122 Spurlock St
Residential mechanical permits at 3122 Spurlock St cover replacement of an HVAC coil and, later, the condenser and coil. The coil replacement was permitted May 27, 2025, under permit RES-MEC-25-000365; the condenser and coil replacement was permitted August 17, 2026, under RES-MEC-26-004475.
Summarized from City of Dallas records · updated Aug 17, 2026
- Projects
- 2
- 2 filings
- Latest filing
- Aug 17, 2026
- since May 27, 2025
- Largest scope
- —
- Listed value
- —
Permit & project history
2 projectsSources: City of Dallas
Questions about 3122 Spurlock St
What is being done at 3122 Spurlock St in Dallas?
City of Dallas permits indicate HVAC component replacements at this residential address: a coil and, later, the condenser and coil.
When was the latest permit filed for 3122 Spurlock St?
The latest listed permit is RES-MEC-26-004475, dated August 17, 2026. It covers replacing the condenser and coil.
Was a new home permitted at 3122 Spurlock St?
The records provided list residential mechanical permits, not a permit for new home construction.
What work was permitted at 3122 Spurlock St in 2025?
Permit RES-MEC-25-000365, dated May 27, 2025, covers replacing a coil.
Is a business opening at 3122 Spurlock St?
The available records show residential mechanical work, not a business opening.
Also being built nearby
All of 75223- 3206 Spurlock StNov 10, 2020Electrical repairs · 103 m away
- 3111 Reynolds AveAug 12, 2025Perform gas test, for gas release · 116 m away
- 3214 Spurlock StJan 21, 2026Atmos reconnect · 117 m away
- 3006 Spurlock StFeb 20, 2026Gas test · 121 m away
- 3002 Spurlock StSep 3, 2025Replacing 2 ton gas hvac system · 126 m away
- 3014 Reynolds AveAug 28, 2025Scope of work by construction phase:1. pre-construction planning & permitting• perform manual j load calculation for heating/cooling loads.• prepare manual d duct design for air distribution.• select hvac equipment per manual s sizing standards.• submit equipment specifications, cut sheets, and duct layout with permit package to city of dallas.• coordinate with builder/general contractor for mechanical chase, soffit, and utility penetration planning.2. rough-in stage (prior to insulation & drywall)• install all supply and return ductwork (r-8 insulated flexible duct for unconditioned spaces, per dallas/).• install sheet metal trunk lines, plenums, and boots per manual d layout.• install refrigerant line sets between indoor air handler/coil and outdoor condensing unit.• run condensate drain lines to approved termination points (with primary & secondary drains per imc §307).• install bathroom exhaust fans, kitchen vent ductwork, and dryer vent duct with exterior termination.• frame and set hvac platform (attic or mechanical closet as per plans).• install combustion air ducts (if gas furnace is used).• install venting for furnaces and water heaters (category iv pvc or b-vent, as applicable).• install gas piping to furnace (if applicable) with sediment traps, shutoff valve, and pressure test per ifgc.• provide fresh air intake/mechanical ventilation system in compliance with dallas energy code.• seal all ductwork connections with mastic or ul-listed tape (per ).3. equipment installation• install air handler/furnace unit in attic or mechanical closet.• install outdoor condensing unit on approved pad or platform, meeting dallas setback and clearance requirements.• connect refrigerant lines, pressure test, and evacuate system prior to charging.• install line-set insulation with uv protection where exposed.• connect electrical whips, disconnects, breakers, and thermostat wiring per nec.• connect gas piping (if applicable), perform pressure test, and verify for leaks.• set and level drain pans with float switches and secondary drains.• install supply registers, return grilles, exhaust grilles in planned locations.________________________________________4. trim-out & final connections• install programmable thermostat(s) per requirements.• install final supply/return registers and grilles.• install bath exhaust fan trim kits and kitchen vent termination hood.• seal penetrations at ceiling/walls for air barrier integrity.• charge refrigerant system per manufacturer specs and dallas code requirements.• balance air distribution system to provide correct airflow to each room.• verify combustion air and venting operation (if gas furnace).• test condensate drains for proper slope and drainage.________________________________________5. testing, commissioning & final inspection• perform duct leakage testing per (? 4 cfm/100 sq ft at 25 pa).• perform airflow balancing for proper cfm per room.• test gas piping and connections for leaks.• verify thermostat and system operational controls.• provide manufacturer startup sheets, equipment model/serials, and balancing report to homeowner and inspector.• schedule city of dallas final inspection for mechanical systems.________________________________________owner-supplied vs. contractor-supplied• contractor will provide and install all hvac equipment, ductwork, registers, grills, refrigerant piping, gas piping, and associated materials unless otherwise noted.• builder/homeowner to coordinate mechanical chase framing and access to electrical service.exclusions• removal of asbestos or hazardous materials.• structural modifications not shown in hvac plans.• utility company fees for gas or electrical service upgrades · 152 m away
- 3203 Reynolds AveNov 10, 2026Nsfaa-bathroom addition · 153 m away
- 3218 Reynolds AveSep 12, 2025Remove all felt and replace with synthetic felt. remove all shingles and replace with iko architectural shingles. install new ice and water shield. install new drip edge. limited lifetime warranty · 164 m away
- 3226 Reynolds AveNov 10, 2026Install 8 ft. wood picket fence a total of 222 ft. and 13 inches · 175 m away
- 3243 Reynolds AveNov 4, 2026Service upgrade · 206 m away
- 3118 Jerome StNov 10, 2026Nsfaa build new house · 206 m away
- 3111 Jerome StApr 10, 2026Nsfaa permitting for built addition from the past to comply with city of dallas rules and guidelines · 219 m away