2002 Euclid St
Dallas, TX 75206
Balcony waterproofing work permitted at 2002 Euclid St
A City of Dallas permit filed December 1, 2025, covers waterproofing and repairs to a balcony at 2002 Euclid St. The work includes removing tiles and a section of siding, assessing the decking for deterioration, installing flashing and waterproofing layers, and reinstalling the railing.
Summarized from City of Dallas records · updated Dec 1, 2025
- Projects
- 1
- 1 filings
- Latest filing
- Dec 1, 2025
- since Dec 1, 2025
- Largest scope
- —
- Listed value
- —
Permit & project history
1 projectWaterproofing balconythe balcony was constructed without any waterproofing or flashing. tiles were installed directly onto the siding, causing water penetration and damage to the plywood sub-flooror. the interior drywall was also affected due to poor installation.demolitiona section of siding must be removed and properly flashed. all tiles are to be removed along with the hand railing. an assessment of deterioration must be completed to determine and replace any damaged portions of pressure-treated decking.waterproofing and decorative installationall areas must be properly flashed and sealed with zip tape. a waterproofing base sheeting is installed along with a drip edge. a flashing lath is then secured to allow application of the first coat of waterproofing cement. at this stage, slopes are tested, and appropriate cement is applied. a second coat of waterproofing cement is then installed, followed by a rolled-on membrane. finally, a decorative textured coat with paint and sealer is applied, and the rails are reinstalled
Waterproofing balconythe balcony was constructed without any waterproofing or flashing. tiles were installed directly onto the siding, causing water penetration and damage to the plywood sub-flooror. the interior drywall was also affected due to poor installation.demolitiona section of siding must be removed and properly flashed. all tiles are to be removed along with the hand railing. an assessment of deterioration must be completed to determine and replace any damaged portions of pressure-treated decking.waterproofing and decorative installationall areas must be properly flashed and sealed with zip tape. a waterproofing base sheeting is installed along with a drip edge. a flashing lath is then secured to allow application of the first coat of waterproofing cement. at this stage, slopes are tested, and appropriate cement is applied. a second coat of waterproofing cement is then installed, followed by a rolled-on membrane. finally, a decorative textured coat with paint and sealer is applied, and the rails are reinstalled
City of Dallas permitResidential Alteration Addition Permit
Sources: City of Dallas
Questions about 2002 Euclid St
What work is planned at 2002 Euclid St in Dallas?
A residential alteration permit covers balcony waterproofing and repairs. The scope includes removing tiles and siding, checking the decking for damage, and installing flashing and waterproofing materials.
When was the balcony work at 2002 Euclid St permitted?
The City of Dallas permit was filed on December 1, 2025.
What is the permit number for 2002 Euclid St?
The permit number is RES-ALT-ADD-25-001318. It was filed with the City of Dallas on December 1, 2025.
Why is the balcony at 2002 Euclid St being repaired?
The permit description says the balcony lacked waterproofing and flashing, and that water penetration damaged the plywood subfloor and affected interior drywall.
Will the balcony tiles and railing be removed at 2002 Euclid St?
The permit scope says all tiles and the hand railing are to be removed. The railing is to be reinstalled after the waterproofing work.
Is a new building being constructed at 2002 Euclid St?
The filed permit is for a residential alteration and addition, specifically balcony waterproofing and repair work; it does not describe construction of a new building.
Also being built nearby
All of 75206- 2010 Euclid StJul 17, 2025Installed hvac 3.5 ton gas system 95% and 5 ton gas system · 7 m away
- 2015 Euclid StSep 4, 2025Standalone gas test · 17 m away
- 2022 Euclid StJan 15, 2026Ug pool heater gas line on existing pool (adding heater to existing swimming pool) · 18 m away
- 2026 Euclid StSep 4, 2025Standalone gas test · 21 m away
- 1930 Euclid StJul 17, 2026Install/replace 3 ton airhandler - this is for unit #3 the address would not find it with the unit number · 103 m away
- 2015 Summit AveNov 20, 2025New split system hvac in conversion area · 113 m away
- 5601 Sears StNov 12, 2025Permit to create a raised wall around drain and installing a lid on said drain in order to bring location up to city code.“ · 113 m away
- 2018 Mcmillan AveOct 21, 2026Gas test · 114 m away
- 1922 Euclid StMay 6, 2026Work being performed on unit c · 114 m away
- 1918 Euclid StJun 17, 2025Hvac unit replacement · 119 m away
- 2007 Mcmillan AveJan 20, 2021Build swimming pool and spa · 127 m away
- 1907 Euclid StSep 15, 2020Change service · 135 m away