Recent · latest filing May 2026Residential
3328 W Clarendon Dr
Dallas, TX 75211
Roof replacement permitted at 3328 W Clarendon Dr
A permit to replace the entire roof at 3328 W Clarendon Dr was filed on May 21, 2026. The City of Dallas record lists it as a residential roofing permit, not a new-home construction project.
Summarized from City of Dallas records · updated May 21, 2026
- Projects
- 1
- 1 filings
- Latest filing
- May 21, 2026
- since May 21, 2026
- Largest scope
- —
- Listed value
- —
Permit & project history
1 projectSources: City of Dallas
Questions about 3328 W Clarendon Dr
What work is planned at 3328 W Clarendon Dr?
A City of Dallas permit filed May 21, 2026, describes replacing the entire roof.
When was the roof replacement permitted at 3328 W Clarendon Dr?
The residential roofing permit was filed on May 21, 2026.
What is the permit number for the roof work at 3328 W Clarendon Dr?
The permit number is RES-ROOF-26-000791. It was filed with the City of Dallas on May 21, 2026.
Is a new home being built at 3328 W Clarendon Dr?
The available City of Dallas record is for replacing the entire roof, not for new-home construction.
How much will the roof replacement at 3328 W Clarendon Dr cost?
The permit record does not include a reported valuation or project cost.
Also being built nearby
All of 75211- 3307 W Clarendon DrJun 27, 2025Replace stove connector and test · 14 m away
- 3323 W Clarendon DrAug 4, 2026Replace existing gas line from gas meter and reconnect equipment as per code.replace existing water heater with a new one and bring up to code · 16 m away
- 3333 Thibet StSep 24, 2026Installed new hvac system · 88 m away
- 3331 Ivandell AveJul 1, 2026Gas pressure test · 124 m away
- 1104 S Westmoreland RdOct 15, 2025Prepare the existing roof system for recover by perforating the existing modified roof system every100 sq ft using a ¾" drill bit, remove any sediment and loose debris. • remove all marked areas of wet insulation that was found present during the moisture scan (approx 2,000 sq ft) all roofing wet insulation will be removed down to the metal deck and new 3" polyiso will be installed. • over the existing roof system furnish, mechanically attach a ½" hd polyiso cover board. all boards will be fastened @ 6 fasteners per 4'x8' board. • furnish and install new 10'x100' carlisle 60 mil tpo membrane. all membrane will be fastened using seam plates and hd fasteners all seams will be fastened @ 12" oc throughout the entire roof area. 2 wind rows will be installed at all perimeter edges at 5'oc. all wind rows will be fastened @ 12" oc. • remove the existing wall flashings and install and mechanically attached a new ¼" dens deck primed cover boards. adhere tpo membrane over dens deck and install new termination bar and counter flashings. • remove and discard 2 abandoned rail curbs and infill with new insulation to match existing roof height. • cover all vertical parapet wall joints with new reinforced, elastomeric three-course (mastic/fabric/mastic) flashing. new elastomeric flashing to extend from top of new surface-mounted counterflashing to the outside top edge of the parapet. mask both sides and extend new elastomeric flashing to approximately 3" past both edges of the panel joint or previously applied joint sealants/coatings, whichever is greater. • install new tpo coated l metal at the west parapet wall and vertical rising walls. mechanically attach metal flange through the new roof assembly at 4" oc using stainless steel, pan head screws • remove and replace 3 rows of the existing shingles where the shingle roof sections are tied in with the new tpo sections. all details will be installed per carlise detail u-13f • remove and replace all damaged shingles. (10 ea.). • furnish and install new leader heads, scuppers and downspouts using 24ga sheet metal (owner to select color). • furnish and install new tpo wall-pads at all service side of mechanical units and roof access points. • flash all curbs, pipes and penetrations per manufacture's specifications · 141 m away
- 1020 S Westmoreland RdAug 18, 2025Work order #153484perform backflow testing · 172 m away
- 3223 Aster StJun 29, 2026Gas test customer recently bought house and per atmos needed to have gas pressure test done and city inspection before they come out · 194 m away
- 3338 Burlingdell AveFeb 13, 2026Gas test with gas release · 218 m away
- 3326 Burlingdell AveOct 10, 2025Replace 200a meter base, surge and upgrade grounding · 219 m away
- 3319 Burlingdell AveJul 7, 2026Install new panel & meter · 233 m away
- 1207 S Westmoreland RdFeb 17, 2026Gas test · 236 m away
- 3121 Aster StDec 30, 2020Install new hvac · 312 m away