2618 Martin Luther King Jr Blvd
Dallas, TX 75215
2618 Martin Luther King Jr Blvd: 1 project on record
City of Dallas lists 1 filing across 1 project at 2618 Martin Luther King Jr Blvd, Dallas, TX 75215. The most recent, filed January 19, 2021, covers: “Replace or modify existing hvac”.
Compiled from City of Dallas records · updated Jan 19, 2021
- Projects
- 1
- 1 filings
- Latest filing
- Jan 19, 2021
- since Jan 19, 2021
- Largest scope
- —
- Listed value
- $193
- partial · often understated
Permit & project history
1 projectSources: City of Dallas
Questions about 2618 Martin Luther King Jr Blvd
What is being built at 2618 Martin Luther King Jr Blvd?
The latest filing (City of Dallas permit 2101193014, January 19, 2021) covers replace or modify existing hvac.
How many permits and filings does 2618 Martin Luther King Jr Blvd have?
1 filing across 1 project, from January 19, 2021 to January 19, 2021.
How much is the construction at 2618 Martin Luther King Jr Blvd worth?
Permits at this address list about $193 in valuations. Permit valuations are often partial and understate total project cost.
Is there other construction near 2618 Martin Luther King Jr Blvd?
Yes. Nearby filings include 2614 Martin Luther King Jr Blvd (testing the gas line to bring it back up to service, Jul 22, 2026); 2612 Martin Luther King Jr Blvd (hvac like for like replacement with electrical update of 50+ year old building to current code compliance. currently, (7) condensing units sit on the ground caged but not truly secured. we're using side discharge condensing units on wall mounts 10' from ground level- increasing security by access. and side discharge units have far less copper in their design. (3) roof top units will be replaced like for like. there will no vrf or doas modifications. overall building mechanical systems will remain air-to-air, Jul 22, 2026); 2610 Martin Luther King Jr Blvd (commercial hvac replacement at an existing occupied building. remove and replace existing rooftop packaged hvac units with like-for-like equipment of equivalent nominal capacity, fuel type and electrical characteristics, installed on existing roof curbs or approved curb adapters and connected to existing duct systems. remove and replace seven existing first-floor split hvac systems, including matched indoor furnaces, evaporator coils, controls and outdoor condensing units. relocate the seven outdoor condensing units from existing grade-level locations to engineered exterior wall-mounted support brackets approximately 10 feet above finished grade for security. reuse existing duct distribution. include refrigerant piping, condensate disposal, gas and electrical reconnections, controls, startup and commissioning. no change of use or occupancy. no vrf or doas work, Jul 22, 2026).
How do I get alerts for new permits at 2618 Martin Luther King Jr Blvd?
Watch this address on groundranger and you'll get an email when a new permit or project filing appears here or nearby.
Also being built nearby
All of 75215- 2614 Martin Luther King Jr BlvdJul 22, 2026Testing the gas line to bring it back up to service · 6 m away
- 2612 Martin Luther King Jr BlvdJul 22, 2026Hvac like for like replacement with electrical update of 50+ year old building to current code compliance. currently, (7) condensing units sit on the ground caged but not truly secured. we're using side discharge condensing units on wall mounts 10' from ground level- increasing security by access. and side discharge units have far less copper in their design. (3) roof top units will be replaced like for like. there will no vrf or doas modifications. overall building mechanical systems will remain air-to-air · 9 m away
- 2610 Martin Luther King Jr BlvdJul 22, 2026Commercial hvac replacement at an existing occupied building. remove and replace existing rooftop packaged hvac units with like-for-like equipment of equivalent nominal capacity, fuel type and electrical characteristics, installed on existing roof curbs or approved curb adapters and connected to existing duct systems. remove and replace seven existing first-floor split hvac systems, including matched indoor furnaces, evaporator coils, controls and outdoor condensing units. relocate the seven outdoor condensing units from existing grade-level locations to engineered exterior wall-mounted support brackets approximately 10 feet above finished grade for security. reuse existing duct distribution. include refrigerant piping, condensate disposal, gas and electrical reconnections, controls, startup and commissioning. no change of use or occupancy. no vrf or doas work · 12 m away
- 2606 Martin Luther King Jr BlvdJul 28, 2026Partial to total demolition of existing installation that feeds existing ac units, also new installation requires emt conduit, disconnects and partial to total wiring to be run for new ac units that are going to be installed for hvac contractor · 17 m away
- 3011 Myrtle StSep 17, 2026House has burnt down to pile of debris. will attach pictures. remove all debris from house and shed · 116 m away
- 2633 Peabody AveAug 25, 2026New hvac · 117 m away
- 3016 Myrtle StJun 26, 2026Nsfaa new build · 130 m away
- 2602 Peabody AveSep 18, 2025Gas test · 130 m away
- 2606 South BlvdJan 13, 2021Remodel existing plumbing · 133 m away
- 2707 Martin Luther King Jr BlvdSep 6, 2026Service release no work 2707 martin luther king jr blvd ste 100 dallas, tx 75215 · 137 m away
- 2617 South BlvdOct 30, 2026Gas test · 145 m away
- 2621 South BlvdSep 11, 2020Electrical repairs · 145 m away