groundranger
Recent · latest filing Jun 2026Commercial

6618 Collville Ave

Dallas, TX 75235

Screen wall replacing fence at an existing Oncor substation

A permit indicates that an existing chain-link fence at an Oncor substation will be replaced with an eight-foot precast ledgestone screen wall topped with three strands of barbed wire. The City of Dallas permit was filed June 2, 2026.

Summarized from City of Dallas records · updated Jun 2, 2026

Projects
1
1 filings
Latest filing
Jun 2, 2026
since Jun 2, 2026
Largest scope
—
Listed value
—

Permit & project history

1 project
  1. This submittal details the replacement of an existing chain-link fence with an eight-foot precast ledgestone screen wall topped with three strands of barbed wire at an existing oncor substation (parcel ids: 00000222739000000; 00000222754000000; 00000222742000000; 00000222745000000; 00000222748000000; 00000222751000000; 00000222757000000; 00000222760000000; 00000222763000000). the structure is supported by 18-inch diameter, 10-foot-deep piers with centrally embedded astm a992 grade 50 steel posts and wall panels maintaining a three (3) to six (6)-inch bottom clearance. engineered for 135 to 140 mph winds per city of dallas and asce 7-16 requirements, the design complies with aci 318-08 and the pci design manual sixth edition. materials include 5,000 psi concrete for panels and caps (4,000 psi stripping), 8,000 psi non-shrink grout, astm a615 grade 60 rebar and 60 ksi smooth welded wire mesh. hardware features 12-inch flared loop coil inserts with a 7,500-pound pull strength

    This submittal details the replacement of an existing chain-link fence with an eight-foot precast ledgestone screen wall topped with three strands of barbed wire at an existing oncor substation (parcel ids: 00000222739000000; 00000222754000000; 00000222742000000; 00000222745000000; 00000222748000000; 00000222751000000; 00000222757000000; 00000222760000000; 00000222763000000). the structure is supported by 18-inch diameter, 10-foot-deep piers with centrally embedded astm a992 grade 50 steel posts and wall panels maintaining a three (3) to six (6)-inch bottom clearance. engineered for 135 to 140 mph winds per city of dallas and asce 7-16 requirements, the design complies with aci 318-08 and the pci design manual sixth edition. materials include 5,000 psi concrete for panels and caps (4,000 psi stripping), 8,000 psi non-shrink grout, astm a615 grade 60 rebar and 60 ksi smooth welded wire mesh. hardware features 12-inch flared loop coil inserts with a 7,500-pound pull strength

    City of Dallas permitCommercial Accessory Structure Permit
    Record
    COM-ACC-26-000145
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro

Sources: City of Dallas

Questions about 6618 Collville Ave

What is being built at 6618 Collville Ave?

A City of Dallas permit describes replacing an existing chain-link fence at an Oncor substation with an eight-foot precast ledgestone screen wall topped with three strands of barbed wire. The permit was filed June 2, 2026.

Is a new building going up at 6618 Collville Ave?

The permit describes a fence replacement at an existing Oncor substation, not a new building. It is permit COM-ACC-26-000145, filed June 2, 2026.

What kind of wall is planned at the Oncor substation?

The permit describes an eight-foot precast ledgestone screen wall topped with three strands of barbed wire, replacing an existing chain-link fence.

What is being built near Highland Park United Methodist Church Campus Updates?

A permit for 6618 Collville Ave, about 69 meters from the church campus, describes replacing a chain-link fence at an existing Oncor substation with a precast ledgestone screen wall. It was filed June 2, 2026.

What is permit COM-ACC-26-000145 for?

The City of Dallas permit is for replacing an existing chain-link fence at an Oncor substation with an eight-foot precast ledgestone screen wall topped with three strands of barbed wire. It was filed June 2, 2026.

Also being built nearby

All of 75235
Get alerts for 6618 Collville Ave